Amalgam Research - Dental Fillings, Dentistry, Side-effects

Amalgam Research Today is a free monthly online journal that collates and summarizes the latest research about Amalgam, including details on dental fillings, dentistry, side-effects.


Amalgam Research Today

Home

View Latest Issue

Information About Amalgam

Books on Amalgam

Advertising in Research Today

View Other Research Today Publications



A comparison of three different methods for the quantification of the in vitro wear of dental materials.

Heintze SD, Cavalleri A, Forjanic M, Zellweger G, Rousson V

R&D, In Vitro Laboratory, Ivoclar-Vivadent, Schaan, Liechtenstein. siegward.heintze@ivoclarvivadent.com

OBJECTIVE: Different approaches are utilized to quantify the wear generated on flat specimens with a wear simulator. However, there are no systematic studies comparing different wear quantification methods with a series of materials that exhibit different wear rates. METHODS: Sixteen restorative materials, including 14 composites (BelleGlass, Chromasit, Estenia, Esthet-X, Four Seasons, Heliomolar RO, Heliomolar HB, Herculite XRV, InTen-S, Point 4, SureFil, Targis cured at 95 and 130 degrees C, Tetric Ceram) as well as an amalgam (Amalcap) and a ceramic (Empress) material, were subjected to attrition wear against standardized Empress antagonists in the Willytec wear simulator (120,000 cycles, 5 kg, 1.6 Hz). The volume and maximal vertical loss were quantified directly on the specimens with a profilometry device (Perthometer) and the FRT MicroProf optical sensor. After the fabrication of plaster replicas, the loss was also determined with a 3D laser scanning device. For the statistical analysis, the data were subjected to a logarithmic transformation. Intraclass correlation was calculated to measure the agreement among all three methods, while limits of agreement were used to compare one method against another. RESULTS: There was a very good agreement between all three quantification methods for both volume and vertical loss. The mechanical sensor measured consistently higher values compared to the optical sensors for the volume loss (correction factor 0.95), whereas for the vertical loss, consistently lower values were obtained (correction factor 1.17). However, the ranking of the materials was only marginally influenced by the quantification method. SIGNIFICANCE: All three sensors are suitable for the quantification of wear facets. Due to speed and simplicity, the laser sensor has greater advantages over the two other sensors.

Published 4 October 2006 in Dent Mater, 22(11): 1051-62.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Amalgam Research Today. All Rights Reserved.



Amalgam Research Today Archive:

Volume 1 (2005)
  Issue 1 (March)
  Issue 2 (April)
  Issue 3 (May)
  Issue 4 (June)
  Issue 5 (July)
  Issue 6 (August)
  Issue 7 (September)
  Issue 8 (October)
  Issue 9 (November)
  Issue 10 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)



Amalgam Books

Solving the MS Mystery: Help, Hope and Recovery

Solving the MS Mystery: Help, Hope and Recovery